- 01 May, 2012 1 commit
-
-
Miguel Angel Ajo authored
-
- 30 Apr, 2012 1 commit
-
-
Miguel Angel Ajo authored
-
- 27 Apr, 2012 3 commits
-
-
jean-pierre charras authored
-
jean-pierre charras authored
-
jean-pierre charras authored
-
- 26 Apr, 2012 4 commits
-
-
jean-pierre charras authored
-
jean-pierre charras authored
All: change MILS_TO_IU_SCALING_FACTOR constant to IU_PER_MILS ( and MM_TO_IU_SCALING_FACTOR to IU_PER_MM) Also fix bug 985654.
-
jean-pierre charras authored
All: change MILS_TO_IU_SCALING_FACTOR constant to IU_PER_MILS ( and MM_TO_IU_SCALING_FACTOR to IU_PER_MM) Also fix bug 985654.
-
jean-pierre charras authored
All: change MILS_TO_IU_SCALING_FACTOR constant to MILS_PER_IU ( and MM_TO_IU_SCALING_FACTOR to MM_PER_IU) Also fix bug 985654.
-
- 25 Apr, 2012 3 commits
-
-
jean-pierre charras authored
-
jean-pierre charras authored
Other scaling factors (MILS_TO_IU_SCALING_FACTOR and DECIMILS_TO_IU_SCALING_FACTOR) also defined only in convert_to_biu.h. Allows different scaling value for Gerbview. Needs more tests.
-
Dick Hollenbeck authored
solution to see that it was not pre-computing constants when used in static initializers. So we have two use cases, and need two solutions to be optimal, since the compiler is too stupid to do the right thing. I think we need something else for compile time computable constants, to be optimal in both use cases. There is quite a bit of code savings by using a macro for that situation from my testing. To fully capitalize on this, we need to go back and make Mm2mils() and what not macros also, or have MACRO versions of them too.
-
- 24 Apr, 2012 3 commits
-
-
Miguel Angel Ajo authored
-
Dick Hollenbeck authored
-
Dick Hollenbeck authored
-
- 23 Apr, 2012 2 commits
-
-
Dick Hollenbeck authored
as a starting point * Make double Distance() take double arguments and remove internal range checking. * Start on EDA_DRAW_FRAME::AdjustScrollBars() and use "double" for most all calculations in anticipation of setting INT_MAX INT_MIN limits eventually.
-
Miguel Angel Ajo authored
-
- 22 Apr, 2012 2 commits
-
-
Wayne Stambaugh authored
* Move board item object Format() functions into PCB_IO object. * Change file format to use layer names instead of numbers. * Change file extension to kicad_pcb.
-
Miguel Angel Ajo authored
-
- 21 Apr, 2012 1 commit
-
-
Miguel Angel Ajo authored
-
- 20 Apr, 2012 1 commit
-
-
Miguel Angel Ajo authored
-
- 19 Apr, 2012 3 commits
-
-
Dick Hollenbeck authored
-
Dick Hollenbeck authored
-
Dick Hollenbeck authored
// This provides better project control over rounding to int from double // than wxRound() did. This scheme provides better logging in Debug builds // and it provides for compile time calculation of constants. #include <stdio.h> #include <assert.h> #include <limits.h> //-----<KiROUND KIT>------------------------------------------------------------ /** * KiROUND * rounds a floating point number to an int using * "round halfway cases away from zero". * In Debug build an assert fires if will not fit into an int. */ #if defined( DEBUG ) // DEBUG: a macro to capture line and file, then calls this inline static inline int KiRound( double v, int line, const char* filename ) { v = v < 0 ? v - 0.5 : v + 0.5; if( v > INT_MAX + 0.5 ) { printf( "%s: in file %s on line %d, val: %.16g too ' > 0 ' for int\n", __FUNCTION__, filename, line, v ); } else if( v < INT_MIN - 0.5 ) { printf( "%s: in file %s on line %d, val: %.16g too ' < 0 ' for int\n", __FUNCTION__, filename, line, v ); } return int( v ); } #define KiROUND( v ) KiRound( v, __LINE__, __FILE__ ) #else // RELEASE: a macro so compile can pre-compute constants. #define KiROUND( v ) int( (v) < 0 ? (v) - 0.5 : (v) + 0.5 ) #endif //-----</KiROUND KIT>----------------------------------------------------------- // Only a macro is compile time calculated, an inline function causes a static constructor // in a situation like this. // Therefore the Release build is best done with a MACRO not an inline function. int Computed = KiROUND( 14.3 * 8 ); int main( int argc, char** argv ) { for( double d = double(INT_MAX)-1; d < double(INT_MAX)+8; d += 2.0 ) { int i = KiROUND( d ); printf( "t: %d %.16g\n", i, d ); } return 0; }
-
- 18 Apr, 2012 2 commits
-
-
Dick Hollenbeck authored
-
jean-pierre charras authored
-
- 17 Apr, 2012 6 commits
-
-
Dick Hollenbeck authored
-
Dick Hollenbeck authored
-
Dick Hollenbeck authored
-
Dick Hollenbeck authored
*) for footprint access into *.mod files and *) BOARD save/load The item_io.cpp and ioascii.cpp have been set off to the side for reference as *.notused, for awhile. The CMake options USE_NEW_PCBNEW_LOAD and USE_NEW_PCBNEW_SAVE are gone, this is now the mandatory usage of the LEGACY_PLUGIN. This should reduce code maintenance for awhile until the s-expression plugin comes into play. But at least for legacy format, there is not two code bodies to maintain any more. A new LEGACY_PLUGIN footprint library caching scheme is in place which needs some testing. It should not be any faster, but might give better results in a networked environment if there is *.mod files on the server.
-
Dick Hollenbeck authored
-
Dick Hollenbeck authored
-
- 16 Apr, 2012 5 commits
-
-
Wayne Stambaugh authored
* Remove internal units from BASE_SCREEN and it's derivatives. * Remove internal units from EDA_DRAW_FRAME and it's derivatives. * Use build time code to replace internal units conversions. * Fix scaling bug in page layout sample window that I created in my last commit.
-
Wayne Stambaugh authored
* Move all convert from user to internal units into base_units.cpp. * Remove internal units parameters from all moved conversion functions. * Revise all source code that calls the moved conversion functions. * Remove internal units from all dialog text control helper classes.
-
jean-pierre charras authored
Kicad manager: code cleaning. Dead code removed and minor fixes. support of new .kicad_brd extension.
-
Dick Hollenbeck authored
-
Wayne Stambaugh authored
* Scale page reference border and title block, grid sizes, and zoom factors correctly for nanometers.
-
- 15 Apr, 2012 1 commit
-
-
lajos kamocsay authored
Other minor fixes.
-
- 14 Apr, 2012 1 commit
-
-
Miguel Angel Ajo authored
-
- 13 Apr, 2012 1 commit
-
-
Wayne Stambaugh authored
* Move all convert from internal to user units functions into separate file. * Remove internal units parameter from all moved conversion functions. * Revise all source code that calls the moved conversion functions. * Compile these conversion routines separately for the appropriate pcb or schematic internal units. * Move internal units specific status bar update code into the appropriate application for updating the status bar. * Move millimeter user units rounding function to common.cpp.
-