Loading recipes-core/init-tempmon/files/init_tempmon.py +20 −10 Original line number Diff line number Diff line Loading @@ -62,6 +62,7 @@ class temp_monitor(): out_path_prefix, out_fnames): self.is_fan_on = False self.is_vp5_enabled = False self.is_10389_present = True self.ctrl_path_prefix = ctrl_path_pref self.ctrl_fnames = ctrl_file_names self.hwmon_path_prefix = hwmon_path_pref Loading Loading @@ -107,13 +108,16 @@ class temp_monitor(): return False for key, val in self.ctrl_fnames.items(): if not os.access(self.ctrl_path_prefix + val, F_OK): if key == "gpio_fn": self.is_10389_present = False else: print "Failed to open sysfs file: '%s%s'" % (self.ctrl_path_prefix, val) return False return True def shutdown(self): """ Turn system off. This function will be called continuously until the system is turn off. Turn system off. This function will be called continuously until the system is turned off. """ subprocess.call(["/sbin/shutdown", "-hP", "now"]) Loading @@ -123,20 +127,26 @@ class temp_monitor(): @param ctrl: can be "on" or "off" to turn fan on or off """ if ctrl is "on": with open(self.ctrl_path_prefix + self.ctrl_fnames["vp5_en_fn"], "r+") as f: """ check if +5V is active and turn it on if it is not (it should not happen) """ with open(self.ctrl_path_prefix + self.ctrl_fnames["vp5_en_fn"], "r+") as f: channels = f.read() if channels.find("vp5") == -1: f.write("vp5") f.flush() if self.is_10389_present: with open(self.ctrl_path_prefix + self.ctrl_fnames["gpio_fn"], 'w') as f: f.write(self.fan_cmd["fan_cmd_on"]) f.flush() self.is_fan_on = True elif ctrl is "off": if self.is_10389_present: with open(self.ctrl_path_prefix + self.ctrl_fnames["gpio_fn"], 'w') as f: f.write(self.fan_cmd["fan_cmd_off"]) f.flush() else: with open(self.ctrl_path_prefix + self.ctrl_fnames["vp5_dis_fn"], 'w') as f: f.write("vp5") f.flush() self.is_fan_on = False else: print "'%s': unrecognized command: '%s'" % (__name__, ctrl) Loading Loading
recipes-core/init-tempmon/files/init_tempmon.py +20 −10 Original line number Diff line number Diff line Loading @@ -62,6 +62,7 @@ class temp_monitor(): out_path_prefix, out_fnames): self.is_fan_on = False self.is_vp5_enabled = False self.is_10389_present = True self.ctrl_path_prefix = ctrl_path_pref self.ctrl_fnames = ctrl_file_names self.hwmon_path_prefix = hwmon_path_pref Loading Loading @@ -107,13 +108,16 @@ class temp_monitor(): return False for key, val in self.ctrl_fnames.items(): if not os.access(self.ctrl_path_prefix + val, F_OK): if key == "gpio_fn": self.is_10389_present = False else: print "Failed to open sysfs file: '%s%s'" % (self.ctrl_path_prefix, val) return False return True def shutdown(self): """ Turn system off. This function will be called continuously until the system is turn off. Turn system off. This function will be called continuously until the system is turned off. """ subprocess.call(["/sbin/shutdown", "-hP", "now"]) Loading @@ -123,20 +127,26 @@ class temp_monitor(): @param ctrl: can be "on" or "off" to turn fan on or off """ if ctrl is "on": with open(self.ctrl_path_prefix + self.ctrl_fnames["vp5_en_fn"], "r+") as f: """ check if +5V is active and turn it on if it is not (it should not happen) """ with open(self.ctrl_path_prefix + self.ctrl_fnames["vp5_en_fn"], "r+") as f: channels = f.read() if channels.find("vp5") == -1: f.write("vp5") f.flush() if self.is_10389_present: with open(self.ctrl_path_prefix + self.ctrl_fnames["gpio_fn"], 'w') as f: f.write(self.fan_cmd["fan_cmd_on"]) f.flush() self.is_fan_on = True elif ctrl is "off": if self.is_10389_present: with open(self.ctrl_path_prefix + self.ctrl_fnames["gpio_fn"], 'w') as f: f.write(self.fan_cmd["fan_cmd_off"]) f.flush() else: with open(self.ctrl_path_prefix + self.ctrl_fnames["vp5_dis_fn"], 'w') as f: f.write("vp5") f.flush() self.is_fan_on = False else: print "'%s': unrecognized command: '%s'" % (__name__, ctrl) Loading