Commit 0f09c15f authored by jean-pierre charras's avatar jean-pierre charras

Pad editor dialog: Better tests and error messages about issues in pad...

Pad editor dialog: Better tests and error messages about issues in pad settings. Fis also an other hard to translate error messge.
parent 152c97a3
......@@ -673,11 +673,11 @@ bool DIALOG_PAD_PROPERTIES::padValuesOK()
}
LAYER_MSK padlayers_mask = m_dummyPad->GetLayerMask();
if( ( padlayers_mask == 0 ) && ( m_dummyPad->GetAttribute() != PAD_HOLE_NOT_PLATED ) )
error_msgs.Add( _( "Error: pad has no layer and is not a mechanical pad" ) );
padlayers_mask &= (LAYER_BACK | LAYER_FRONT);
if( padlayers_mask == 0 )
error_msgs.Add( _( "Error: pad has no layer" ) );
if( ( padlayers_mask & (LAYER_BACK | LAYER_FRONT) ) == 0 )
{
if( m_dummyPad->GetDrillSize().x || m_dummyPad->GetDrillSize().y )
{
......@@ -715,20 +715,21 @@ bool DIALOG_PAD_PROPERTIES::padValuesOK()
switch( m_dummyPad->GetAttribute() )
{
case PAD_STANDARD : // Pad through hole, a hole is expected
case PAD_HOLE_NOT_PLATED: // Not plated, but through hole, a hole is expected
case PAD_STANDARD : // Pad through hole, a hole is also expected
if( m_dummyPad->GetDrillSize().x <= 0 )
error_msgs.Add( _( "Incorrect value for pad drill (too small value)" ) );
error_msgs.Add( _( "Error: Through hole pad: drill diameter set to 0" ) );
break;
case PAD_CONN: // Connector pads are smd pads, just they do not have solder paste.
if( (padlayers_mask & SOLDERPASTE_LAYER_BACK) ||
(padlayers_mask & SOLDERPASTE_LAYER_FRONT) )
error_msgs.Add( _( "Error: Connector pads are not on the solder paste layer\n"
"Use SMD pads instead" ) );
// Fall trough
case PAD_SMD: // SMD and Connector pads (One external copper layer only)
if( (padlayers_mask & LAYER_BACK) && (padlayers_mask & LAYER_FRONT) )
error_msgs.Add( _( "Error: only one copper layer allowed for this pad" ) );
break;
case PAD_CONN: // connectors can have pads on "All" Cu layers.
break;
case PAD_HOLE_NOT_PLATED: // Not plated
error_msgs.Add( _( "Error: only one copper layer allowed for SMD or Connector pads" ) );
break;
}
......@@ -738,6 +739,7 @@ bool DIALOG_PAD_PROPERTIES::padValuesOK()
dlg.ListSet( error_msgs );
dlg.ShowModal();
}
return error_msgs.GetCount() == 0;
}
......
......@@ -2426,8 +2426,9 @@ ZONE_CONTAINER* PCB_PARSER::parseZONE_CONTAINER() throw( IO_ERROR, PARSE_ERROR )
NeedSYMBOLorNUMBER();
if( zone->GetNet()->GetNetname() != FromUTF8() )
{
wxString msg = _( "There is a zone that belongs to a not "
"existing net (" ) + FromUTF8() + _("), you should verify it." );
wxString msg;
msg.Printf( _( "There is a zone that belongs to a not existing net"
"(%s), you should verify it." ), GetChars( FromUTF8() ) );
DisplayError( NULL, msg );
zone->SetNetCode( NETINFO_LIST::UNCONNECTED );
}
......